DESCRIPTION
This opening system is made of a tubular motor with built-in
control unit with the following characteristics:
It is provided with a 434.15 MHz super-heterodyne radio
receiver.
Up to 48 different channel can be stored on each central unit.
It is driven by means of transmitters PROTEO, DUO, ARTEMIS,
ADLER and DEV-T1.
It is possible to drive the awning / rolling shutter also by mean
of an external push-button (type: Normally Open, each series
or model).
The programming phase can be effected via radio or by means
of an external switch.
It is necessary to use a sesor model WIND, MISTRAL, METEO,
HURRICANE.
FUNCTIONING WITH EXTERNAL WIRED
SWITCH
Pressing the external wired switch, the control unit has the
following functioning logic:
a
a
OPENS
STOPS
CLOSES
FUNCTIONING WITH TRANSMITTERS
At each push button pressure, the functioning logic is the
following.
a
UP:
CLOSES
CLOSES
a
STOP:
STOPS
STOPS
a
DOWN:
OPENS
OPENS
SENSOR ACTIVATION
To activate the sensors function, at least one transmitter must be
stored.
m
IMPORTANT:
Anemometer causes inhibition of functioning of both radio
transmitter and external push button for ca. 8 minutes.
The anemometrical sensor should be installed close to the
awnings, in order to avoid damages in case of very strong
wind.
WORKING TIME OF MOTOR
The control unit stops the motor movement after 2 minutes: in
case of limit switches malfunction this "time out" avoids the
motor overheating.
a
a
STOPS
OPENS ...
a
CLOSES
a
STOPS
a
OPENS
TRANSMITTERS OF THE RANGE
PROTEO / DUO
Using a transmitter of the range PROTEO / DUO it is possible
changing the functions of the control unit controlling the tubular
motor.
The transmitter is equipped with a 10 switches dip-switch thanks
to which it is possible to change the desired functions: set on ON
the switch corresponding to the function required and follow
carefully the dedicated procedure.
WARNING: all the other switches have to be set on OFF
SWITCH
FUNCTION
1
Storage of the transmitters
3
Deletion of all the stored transmitters
7
Storing of the level of intervention of the wind
sensor
8
Programming of the level of intervention of the sun
sensor
10
Programming of the level of temperature
2 - 4 - 5
NOT USED
6 - 9
- 20 -
DIP-SWITCHES
PROG