The product must not be used if it fails to pass the functionality test, is damaged, lacks
expert servicing/maintenance, or if non-original spare parts have been used.

1.2 Liability

In cases of improper or unintended use of the products, Rosenbauer
INTERNATIONAL AG bears no liability. The selection and use of the products are
the sole responsibility of the persons involved.
Product liability claims, warranty claims and claims arising from any liability
Rosenbauer INTERNATIONAL AG bears for these products under the warranty is
deemed void if they are not used, serviced or maintained in accordance with the
operation manual.

2. DEVICE DESCRIPTION

The mask body is made of a special rubber compound, which is softer and guarantees
a more comfortable fit. A number of models are available in smaller sizes.
The breathable air is guided from the plug connector of the mask-helmet combination
through the inhalation valve to the inside of the visor and from there via the control
valves to the inner mask.
The exhaled air is discharged directly into the atmosphere through the exhalation valve.

2.1 Device design

See the associated manual of the mask manufacturer

3. USE

The mask should be kept either on the chest-fitted carrying strap or in the carrying
box.
ATTENTION! The upper rim of the mask should lie directly on the user's forehead. Hair
or the flame guard should be kept clear of the area of the mask seal line. Otherwise
there is a danger of the mask not fitting tightly.
This risk is also present for mask wearers with a beard or deep scars in the seal area.
The tightness of the mask/helmet combination is dependent on the correct mask
size, adjustment of the mask strap (if possible) and helmet liner.
During use of the mask/helmet-combination, the interior of the helmet is to be fitted
exactly to the user's head size. If the interior or the headgear does not firmly sit on the
head during use, there is a potential for a leak at the seal line of the mask.