When the Need Arises

FAQ

Indoor unit
The fl ap does not start swinging
immediately.
• The air conditioner is adjusting the position of the fl ap.
The fl ap will start moving soon.
The air conditioner stops generating
airfl ow during operation.
• Once the set temperature is reached, the airfl ow rate is
reduced and operation stopped in order to avoid
generating cool airfl ow (during heating) or in order to
keep the humidity from rising (during cooling).
Operation will resume automatically when the indoor
temperature rises or falls.
HEAT operation stops suddenly and a
fl owing sound is heard.
• The outdoor unit is defrosting. HEAT operation starts
after the frost on the outdoor unit has been removed.
This can take about 4 to 12 minutes.
Operation does not start soon.
 When
or any direct operation button
was pressed soon after operation was
stopped.
 When the mode was reselected.
• This is to protect the air conditioner.
You should wait for about 3 minutes.
Outdoor unit
The outdoor unit emits water or steam.
 In HEAT operation
• The frost on the outdoor unit melts into water or steam when the air
conditioner is in defrosting operation.
 In COOL or DRY operation
• Moisture in the air condenses into water on the cool surface of the outdoor
unit piping and drips.
27
All manuals and user guides at all-guides.com
Different sounds are heard.
 A sound like fl owing water
 Blowing sound
 Ticking sound
 Whistling sound
 Clicking sound during operation or idle time
 Clopping sound
• This sound is generated because the refrigerant in the
air conditioner is fl owing.
• This is a pumping sound of the water in the air
conditioner and can be heard when the water is
pumped out from the air conditioner during COOL or
DRY operation.
• This sound is generated when the fl ow of the
refrigerant in the air conditioner is switched over.
• This sound is generated when the cabinet and frame
of the air conditioner slightly expand or shrink as a
result of temperature changes.
• This sound is generated when refrigerant fl ows during
defrosting operation.
• This sound is generated when the refrigerant control
valves or the electrical parts operate.
• This sound is heard from the inside of the air conditioner
when the exhaust fan is activated while the room doors are
closed. Open the window or turn off the exhaust fan.