Santon DFS-14 Installationshandbuch Seite 2

Feuerwehr sicherheitsschalters
Vorschau ausblenden Andere Handbücher für DFS-14:

Werbung

CONTENT / INHALT / TENEUR / CONTENIDO / CONTENUTO / INHOUD
CONTENT / INHALT / TENEUR / CONTENIDO / CONTENUTO / INHOUD
2
DFS-14
• Motor driven DC-disconnect switch in enclosure
• Installation manual
DFS-14-W
• Motor driven DC disconnect switch in enclosure
• Installation manual
• 9 x M12 glands
DFS-14-MC4
• Motor driven DC disconnect switch in enclosure
• Installation manual
• Pre-wired on 8 x MC4 connectors
• 1 x M12 gland
DFSHP-14-MC4
• Motor driven DC disconnect switch in enclosure
• Installation manual
• Pre-wired on 8 x MC4 connectors
• 1 x M12 gland
GENERAL NOTICE AND SAFETY INSTRUCTIONS
General notice
equipment.
• Santon shall not be held responsible for any damage caused due to incorrect installation of the product and/or the
misunderstanding of this manual.
without notice.
of personal use.
• To ensure the recycling of all possible materials and proper disposal treatment of components, please return the
product to Santon at end-of-life.
• Check the system regularly (once per 3 months) on faults.
Important safety precautions
Attention! Components in the installations are exposed to high voltages and currents. Follow these instructions carefully
The following regulations and standards are considered applicable and mandatory to read prior to the installation of
electrical equipment:
• International Standards: IEC 60364-7-712 Electrical installations of buildings – Requirements for special installations or
locations – Solar Photovoltaic (PV) power supply systems
• MIS3002: Microgeneration Installation Standard - requirements for contractors undertaking the supply, design,
installation, set to work commissioning and handover of solar photovoltaic (PV) microgeneration systems
• Local building regulations
• Guidelines for lightning and overvoltage protection
Note!
• It is essential to uphold the limits for voltage and current in all possible operating conditions (see page 11; 'Technical
Data'). Also keep in mind the literature on correct dimensioning and sizing of cabling and components.
• All the installation works should be tested in accordance with relevant local legislation at the time of installation.
photovoltaic installations. The DC disconnect switch is used to disconnect the connected strings of the installation in
The DFS needs to be placed as close to the solar panels as possible. Due to its enclosure, the switch is protected
outdoor usage when needed.
NOTE: The switch enclosure may not be installed in direct sunlight or be in direct contact with (continuous) ingress
water.
Normal operation:
The DFS will automatically switch to the off position, breaking the DC connection between the solar panels and the
the on position, restoring the DC connection between the solar panels and the inverter, once the AC power to the DFS is
Special Operation:
If the temperature inside the DFS enclosure exceeds the 100°C, the DFS will automatically switch to OFF to protect the
internal components and create a safe situation. When the installation is checked and the DFS is not affected, the DFS
can be switched ON again by removal and re-applying the AC voltage to the DFS. The DFS will also automatically switch
to OFF if there is an internal failure. If this occurs please try to reset the DFS by removal and re-applying the AC voltage
to the DFS.
If this problem remains, please contact the Santon Support team: solar@santonswitchgear.com
3