We recommend that you write the data here:
Model (MOD.)
Product number (PNC)
Serial number (S.N.)
Technical data
Voltage
Frequency
Installation
Warning! Refer to the Safety chapters.
Building Under
Warning! Only a qualified and competent person
must do the installation of the appliance. If you do
not contact a qualified or competent person, the
guarantee becomes invalid if there is damage.
• Before you install the appliance, fit it with the appli-
cable hob from the table.
Type
KEV 6040
KEV 6042
28
Maximum power
6000 W
7600 W
.........................................
.........................................
.........................................
230 / 400 V
50 Hz
Electrical installation
Warning! Only a qualified and competent person
must do the electrical installation.
The manufacturer is not responsible if you do not
follow safety precautions from the chapter "Safety
information".
This appliance is supplied without a main plug or a
main cable.
The cable
Cable types applicable for installation or replacement:
H07 RN-F, H05 RN-F, H05 RRF, H05 VV-F, H05 V2V2-
F (T90), H05 BB-F.
For the section of the cable refer to the total power (on
the rating plate) and to the table:
Total power
maximum 1380 W
maximum 2300 W
maximum 3680 W
A
B
Section of the cable
3 x 0,75 mm²
3 x 1 mm²
3 x 1,5 mm²