Herunterladen Diese Seite drucken

AEG BS2E 9.6 T Gebrauchsanleitung Seite 8

Atlas copco

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 9
Charging of
batteries
Battery pack
reception
ENGLISH
Connect charger
Charger ready
Insert battery
Battery too cold (less than 0
Maintenance charging until
battery temperature is
above 0
continuous
light
Battery temperature 0
quick charging
flashing
Battery is charged/
Maintenance charging
New battery packs reach full loading capacity after 4 – 5 chargings and
dischargings. Battery packs which have not been used for some time should be
recharged before use.
Note the correct position when inserting
the battery pack. Make sure it is fully
inserted.
The battery clamps of the charger are fed
by mains supply. do not touch the tool with
conducting objects.
BS2E 7.2 T, BS2E 9.6 T, BS2E 12 T, BS2E 14.4 T, POWERBASE 60
8
flashing
o
C)
Battery too hot (over 45
Maintenance charging
allow battery to cool down
o
C
below 45
o
o
C–45
C
flashing
o
C)
o
C, and re-insert

Werbung

loading

Diese Anleitung auch für:

Bs2e 7.2 tPowerbase 60Bs2e 12 tBs2e 14.4 t