TFR 1800-2300-3600
1. Items supplied
1
pond filter with BIOCELL filter insert
1
multiple-jet cascade fountain
1
spout connection
1
/
" double nipple
1
2
2. Technical data
Type
Power supply
Power consumption
Delivery rate max.
Delivery height max.
Immersion depth
Fountain height with cascade fountain max.
For pond volumes up to
Art. No.:
3. Pump design
High-performance, universal, submersible motor
pump for continuous duty in garden ponds.
Oil-free motor
Stator hermetically sealed in casting resin
Permanent magnet rotor runs in water
4. BIOCELL intake filter
The intake filter for the pond filter works with a
BIOCELL filter insert. BIOCELL is a special material
for cleaning water by natural, biological means.
Whereas normal mechanical filters are able only to
trap particles of dirt such as plant remnants or dead
insects and the like, biological filtration actually
breaks down the dirt, including muddy materials. This
decomposition is performed by nitrifying bacteria.
BIOCELL, a porous material developed specially for
biological filtration, provides these bacteria with ideal
conditions for propagation. Toxic organic substances
are transformed inside the BIOCELL into natural
plant nutrients - a natural process that will make a
special contribution to your garden pond's biological
equilibrium.
24.10.2001 12:10 Uhr
Seite 5
TFR 1800
TFR 2300
230V ~ 50Hz
230V ~ 50Hz
27 W
45 W
1900 l/h
2400 l/h
1.75m
2.3 m
3 m
3 m
1.1 m
1.55 m
5000 l
15000 l
36.062.10
36.062.45
5. Safety instructions
Electric shocks can be fatal. It is vital, therefore,
to observe the following instructions:
The pump is to be operated only from a properly
installed socket outlet with earthing contact.
Use of the pump in swimming pools, garden
ponds and fountains as well as within their zone
of protection is permitted only if the electrical
wiring is installed in accordance with VDE 0700
Part 702 and Part 738: Earth-leakage circuit-
breaker (e.l.c.b.) with 30 mA or 10 mA leakage
current. Please ask your electrician.
Caution! Never use the pump when there are
people in the pool.
Pumps with a 3 m power cable are to be used
only inside buildings. Pumps with a 10 m power
cable (H05RN-F minimum) are compulsory for
outdoor use.
Pull out the power plug before starting any
maintenance work.
If the pump cable or plug is ever damaged, the
cable is not to be repaired! In this case you must
stop using the pump.
GB
TFR 3600
230V ~ 50Hz
74 W
3500 l/h
2.8 m
3 m
2.3 m
25000 l
36.062.75