Herunterladen Inhalt Inhalt Diese Seite drucken

Putting Into Operation - EINHELL TFR 1800 Bedienungsanleitung

Teichfilter
Vorschau ausblenden Andere Handbücher für TFR 1800:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
TFR 1800-2300-3600
GB
Take special care not to allow aggressive liquids
or abrasive substances to run through the pump.
Never suspend the pump from the pressure line
or electric cable. Use the eyelet provided for this
purpose.
Protect the pump from freezing temperatures.
Take suitable measures to keep the pump away
from children.
It is prohibited to use cable systems, extension
cables, connection cables or adapters without an
earthing contact.

6. Putting into operation

It is imperative to observe the above safety
regulations when you put the pond filter into
operation.
Place the pond filter on a horizontal surface higher
than the bottom of the pool (this will reduce
excessive soiling by sludge deposits).
Never use the pond filter outside the water.
7. Fountain mode
There are 3 options:
Only the cascade fountain
The cascade fountain together with the water
spout connection for water spectacles
Only the water spout connection for water
spectacles
Operation only with the cascade fountain:
(see Figure 1)
When installing the pond filter in the pond, make sure
that the fountain head projects above the water
surface. If you want to use only the cascade
fountain, turn the shut-off cock (A) of the spout
connection clockwise one quarter of a rotation in
order to close it.
Operation of the cascade fountain and the water
spout connection: (see Figure 1)
Install the pond filter as described above. Additional
water spectacles can be connected to the water
spout connection with a hose of 9 mm inner diameter
or 13 mm diameter.
To open the spout connection, turn the shut-off cock
anticlockwise.
6
24.10.2001 12:10 Uhr
Seite 6
Operation only with the water spout connection:
(see Figure 2)
In this case you must turn the entire connection (B)
through 90°. All the water will then flow through the
spout connection and none through the fountain.
1
2

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Tfr 2300Tfr 360036.062.1036.062.4536.062.75

Inhaltsverzeichnis