Technical Data
Part number ............................................. FF35144 (Typ C), FF35144Z (Typ J)
Voltage ..................................................... 220-240V
Frequency ................................................ 50/ 60 Hz
Rated power ............................................. 1400 W
Max. power ............................................... 1600 W
Air flow at the fan ...................................... 230 m³/h/MG
Negative pressure at the fan ..................... 259 hPa/MG
Air flow at the hose ................................... 150 m³/h/SE
Negative pressure at the hose .................. 236 hPa/SE
Connecting cable ...................................... H05VV F 3 x 1,5
Dimensions (L x W x H) ............................ 45,7 x 40 x 54 cm
Weight ...................................................... 12,7 kg
Type of protection .................................... IP 24
Noise pressure level (L
Sound power level (L
The noise level during operation can exceed 85 dB (A). Wear hearing protection!
Measured values determined in accordance with EN 60335.
3
Function of the Unit
3.1
Overview
Top section
1
Functional plate
2
Rotary switch
2a
Power socket for elec-
2b
tric tools
Volume flow display
2c
(Fill level indicator)
Speed control
2d
Cooling air inlet
3
) ........................ 70 dB (A) ¦ K
pA
) .......................... 81 dB (A) ¦ K
WA
Latch
4
Lock
5
Connecting line
6
Container
7
Suction opening
8
Snap-in locks
9
Wheels
10
ENGLISH
3 dB (A)
pA
3 dB (A)
WA
Steering castors
11
Filter cassettes
12
Motor protecion filter
13
Fleece filter bag
14
Vacuum hose
15
Accessories box
16
Reducer
17
(A)
17