AXIS Q60-E Series
Install the camera on a bracket mount
WARNING
Risk of electric shock. The product shall be grounded using a grounding wire. Make sure
both ends of the grounding wire are in contact with their respective grounding surfaces.
NO
NO TICE
NO
TICE
TICE
To comply with the IP66-rated design of the camera and maintain the IP66 protection,
the supplied RJ45 Push-pull Connector (IP66) shall be used. Alternatively, use the RJ45
IP66-rated cable with premounted connector which is available from your Axis reseller. Do
not remove the plastic network connector shield from the camera.
This product can be mounted with the cables routed through or along the wall or roof.
1. Install the selected bracket according to the instructions supplied with the bracket. If
drilling is required, make sure to use drill bits, screws and plugs that are appropriate for
the material.
2. Secure the camera using the supplied safety wire.
3. Route the network cable and a grounding wire through the holes in the mounting
bracket. Make sure the grounding wire is as short as possible to make the current path
as short as possible.
4. Loosen the grounding screw and remove the washer and cable shoe.