Just Power On
11. SPLIT PHASE FUNCTION
Note:
(1) Please disconnect the AC charging cable for both AC300 units while
binding into split phase box.
(2) Certificated Technician is required to build the split phase system to
power the Sub Panel.
Warning: If you insist to charge the AC300 which has been connected
into split phase box already, please make sure the L1/L2/N wire is set at
the right phase sequence or the AC300 will be damaged.
L: Live wire N: Neutral wire
CONNECTION 1 (Standard Mode)
"Single Phase" is set as the default machine type if you are operating a single
AC300+B300 system. It`s the only and correct setting if a single AC300+B300
is being used. "Machine type" is only used to set for Split Phase, "Split Phase" is
only used for connecting both *2 AC300+B300 (exclusive for AC300 100-120V
Version) bonded 2 pairs of AC300+B300 to one power supply system to double
the output power, voltage, so as to capacity. Please refer to Split Phase Setting
for detailed information.
*1 NEMA L14-30 receptacle, 30A
*2 NEMA TT-30 receptacle, 30A
*4 Standard AC receptacle, 20A