Tragbare stromversorgung
Vorschau ausblenden Andere Handbücher für AC300:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

BLUETTI
Step1: Plug the AC charging cable into the wall outlet.
Step2: Plug the AC charging cable into the AC input port.
Step3:Connect the load to AC300 via AC output port
Note: The output power in Plug-in UPS Mode is subject to the specification of
the current and voltage from home circuit.
a, Standard UPS Mode. b, Time Control UPS Mode.
c, PV Priority UPS Mode. d,Customized UPS Mode.
Eg: Current (15A wire) X Voltage (120V) = 1800W in US
Eg: Current (30A wire) X Voltage (120V) = 3000W in US
10.1.3. Turn On UPS Function
● Select "Setting" on the main touchscreen interface. Select "Next" and select
"Working Mode" to choose UPS Mode.
●The default working mode is "Standard UPS Mode".
10.2. Enable UPS Running Mode
10.2.1 Standard UPS Mode
● The AC300+B300 will power your load directly from the grid and maintain a
100% charge. When grid power fails, the AC300 switches to internal batteries.