Bluetti AC300 Benutzerhandbuch Seite 34

Tragbare stromversorgung
Vorschau ausblenden Andere Handbücher für AC300:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Just Power On
10.2.2. Time Control UPS Mode
● Set the times of the AC300+B300 to be charged via grid power and the
times to run loads from its battery.
Charge Time: Set the time of when the AC300+B300 is to be recharged by
grid to avoid the higher electricity rates.
Discharge Time: Set the time to switch to batteries to power loads connected
to the Sub Panel (Optional Purchase).
● Parameter Setting:
Battery SOC Low: When the remaining capacity of AC300+B300 is under the
preset High/Low battery capacity, AC300+B300 will stop powering connected
loads.
Battery SOC High: The maximum capacity AC300+B300 can be charged via
grid. Remaining capacity will be charged via solar panels, car, lead-acid battery
or second adapter only.
10.2.3. PV Priority UPS Mode
● PV Priority Mode: Recommended for areas with stable grid power. The
battery will be recharged mainly by PV for power savings.
● Note: In PV Priority Mode, AC300 can only be recharged via grid to 30%
capacity, and also discharge to 30% of the capacity (you can tweak it to
100% for full grid charging manually on touchscreen or App) as the "Reserved
capacity for PV charging". And rest of the capacity will be fully charged from
either solar power or 2 adaptors.
31