2

Technical Data

Nominal consumption ................................ 230 V
Performance .............................................. 630 W
Speed ........................................................ 0 – 850 1/min
Spiral rod diameter .................................... Ø 8 and 10 mm
Max. spiral rod diameter ............................ 10 m
Weight ....................................................... approx. 4,7 kg
Protection class ......................................... I
Protection type ........................................... IP 20
Typical A-rated sound level:
Noise pressure level (L
Sound power level (L
The noise level during operation can exceed 85 dB (A). Wear hearing protection! Measured val-
ues determined in accordance with EN 60745-1:2010.
Subject to technical modifications!
3

Function of the Unit

3.1
Overview
1
Chuck
2
Spiral rod holder
3.2
Operating
 Plug mains plug into 230 V / 50 Hz.
Attention! Only run the Standard-Version in "drilling" position.
Attention! Commence cleaning work with low rotational speed and increase if
required.
 Pull the spiral out of the spiral container and insert it into the pipe, which is to be cleaned,
until resistance (obstruction) becomes noticeable.
There must still be approx ca. 20 - 30 cm of spiral between the cleaning device and
the pipe opening. Tighten the spiral chuck.
 Hold the handle of the cleaning unit with one hand.
 Start the drill turning slowly in clockwise direction using the other hand. Increase the rotatio-
nal speed according to the cleaning problem.
 Push the cleaning device with the rotating spiral at intervals against the obstruction.
 Once the spiral has penetrated further into the pipe, stop the rotation (switch machine off),
loosen the spiral chuck, pull the spiral out of the spiral container again by approx. 30 cm,
tighten the spiral chuck and work again at intervals with the rotating spiral against the ob-
struction.
Repeat this procedure until the blockage has been cleared.
3.3

Taking out of service

 The spiral is now pulled out section by section from the pipe and once the clamping chuck
has been loosened, pushed back into the container. A length of approx. 10 - 15 cm of the
spiral remains outside.
 Remove plug from mains socket.
10
All manuals and user guides at all-guides.com
) .......................... 83 dB (A) ¦ K
pA
) ............................ 94 dB (A) ¦ K
WA
Standard version
3 dB (A)
pA
3 dB (A)
WA
3
Drive
ENGLISH
(A)
(B)

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

72525072525z

Inhaltsverzeichnis