2. MouNtING of tHERMoStAt
Remove the control knob (A) (pic. 1).
Screw (B) should be unscrewed and the cover lifted off (pic. 1).
Electrical connections should be made as shown in the wiring
diagram. (pic. 2).
Mount the backing plate. Use only the round holes.
The thermostat can now be filled into the wall box.
screw back frame and cover;
put back the temperature control knob (A).
3. MouNtING of fLooR SENSoR
Place the floor sensor in an approved non conductive installation pipe in
accordance with EN 61386-1, which is embedded in the floor (pic. 3). The
pipe end is sealed and placed in the concrete layer as close as possible
to the surface. The installation pipe must be centred between the heating
cable loops. Sensor cable can be extended by up to 100 m by means of a
separate cable.
4. SEtbACK tEMpERAtuRE
Setback of temperature setting is activated by a 230 V (L) signal from an
external time switch to terminal 5. Setback temperature is fixed 5˚C.