5.3.1 MG: magnetic sensitivity level setting, "MG--0"is off, "MG--9"is the highest. The default is "MG--5".
V800
5.3.2 DD: size sensitivity level setting, "DD--0"is off, "DD--9"is the highest. The default is "DD--5".
5.3.3 DB: double notes sensitivity setting, "DB--0"is off, "DB--9" is the highest. The default is "DB--5".
5.3.4 UV: ultraviolet sensitivity level setting, "UV--0"is off, "UV--9" is the highest. The default is "UV--5".
5.3.5 Slope: slope sensitivity level setting, "Slope--0"is off, "Slope--9" is the highest. The default is "Slope--5".
5.3.6 IR: infrared sensitivity level setting, "IR--0"is off, "IR--9" is the highest. The default is "IR--9".
5.3.7 AUTO: AUTO/MNL counting setting. "0" is the manual counting and "1" is the automatic counting.
5.3.8 SN_CL: serial number USD, "SN_CL--0" is off, "SN_CL--9" is the highest. The default is "SN_CL--0".
5.4 Alarm sound
In the MENU choose ALARM SOUND setting (pic 5-4). Pres CUR or ADD and FACE or BATCH to choose, then press START | ENTER or START || ENTER to
save and once finished press ORIENT or +1/+10 to back to the previous interface.
1.SOUND ON :to turn on the alarm beep and button click sound.
2.SOUND OFF: to turn off the alarm beep and button click sound.
Pic 5-4
13