Herunterladen Inhalt Inhalt Diese Seite drucken

Gerdes Primux Installationsanleitung Seite 44

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Newer PMX box (with RJ45 connector)
These PMX boxes offer wire plugs like the older ones which you can connect as described above.
We recommend using the RJ45 connector, though.
Select the black cable(s) with WD8 plugs on both ends.
1. Plug the end marked 'PrimuX' into the connector(s) on the back of your PrimuX controller
2. Connect the other end to your PMX box
If you need to build your own cable (i.e. a longer one) to connect to the RJ45 connector please
use the connection table below:
PrimuX PIN 3 (green/white) → PMX PIN 4
PrimuX PIN 4 (blue)
PrimuX PIN 5 (blue/white) → PMX PIN 2
PrimuX PIN 6 (green)
Other setups
If your setup differs from those described above please make sure that the connections are made
according to the table below:
PrimuX PIN 3 → TX (controller transmits)
PrimuX PIN 4 → RX (controller receives)
PrimuX PIN 5 → RX (controller receives)
PrimuX PIN 6 → TX (controller transmits)
Connectors
The PrimuX series offers controllers with more than one line per controller. The PrimuX 2S0
II/E for instance supports two lines, the PrimuX 4S0 II/E supports four and the PrimuX 8S0
II/E supports eight lines.
The images below can help you in identifying the connectors for each line. In these images ''C1''
means line 1, ''C2'' means line 2 and so on.
Connectors
→ PMX PIN 1
→ PMX PIN 5