64
1
OFF
Screw
(1A):050
conveyor
ON
motor
(1B):015
Exhaust gas
(1C):018
motor
Ash
cleaning
(P23):000
period
Screw motor: Minimum adjustable value is 0.1 second. The adjustable value for OFF/
ON is 0-9.9 seconds. (1 A) 050, (1B) 015 means that the screw motor stops for 5.0
seconds and works for 1.5 seconds.
Exhaust engine: The adjustable value is 001-0035 (155-240 V). The draught decreases
as the number increases. 001 means the strongest draught, 035 means the weakest
draught.
Ash cleaning period: 000 means OFF, 060 is the highest value. P31:015 ] in the 3rd
power stage means that the exhaust engine runs at maximum power for 15 seconds
after 1 hour to remove the ash.
Note: The above parameters are for your information only, they change
whenthe calorific value of the pellet changes!

Overload protection

There is a fuse in the mains plug on the rear of the furnace to prevent
overvoltage and overcurrent. If the fuse burns out, have it replaced by a
specialist company with an equivalent standard fuse.
Power level
2
3
OFF
OFF
(2A):055
(3A):045
ON
ON
(2B):020
(3B):020
(2C):018
(3C):017
(P27):010
(P31):015
4
5
OFF
OFF
(4A):040
(5A):035
ON
ON
(4B):020
(5B):020
(4C):016
(5C):016
(P35):020
(P39):030