IMPORTANT CHARGING NOTES (ONLY FOR GE 10-B)
1.
Inflator longer life and better performance can be obtained if the battery is charged when the
air temperature is between 18° - 24°C (65°F and 75°F). DO NOT charge the battery with an air
temperature below +4.5°C (+40°F), or above +40.5°C (+105°F). This is important and will prevent
serious damage to the battery.
2.
The charger and battery may become warm to touch while charging. This is a normal condition,
and does not indicate any possible failure.
3.
DO NOT immerse the charger in water or any other liquids.
DO NOT ALLOW ANY LIQUID TO GET INSIDE THE CHARGER.
ELECTRIC SHOCK MAY RESULT.
4.
DO NOT try to charge the battery with any chargers other
than those indicated in this manual. The charger and battery
are specifically designed to work together. THE GE10-B CAN BE
CHARGED DIRECTLY VIA THE CAR CIGARETTE LIGHTER SOCKET.
5.
The charger is not intended for any use other than charging the
inflator battery. Any other use may result in risk of fire, electric shock
or electrocution.
6.
Make sure the cable is located so that it will not be stepped on,
tripped over, or otherwise subjected to damage or stress.
7.
Do not operate the charger with a damaged cable or plug.
8.
Do not operate the charger if it has been damaged in any way.
9.
Do not disassemble the charger. Incorrect reassembly may result
in a risk of electric shock, electrocution or fire.
10.
Never use another charger to charge this product. Always use
original spare parts only.
8. TO INFLATE
1.
Connect the inflator to the power supply (except GE10-B) using the cables provided.
The GE10-3 and GE 10-8 are equipped with a car cigarette lighter plug for direct connection to the
12 Vdc battery.
2.
Connect the air hose to the outlet port, in the direction of the arrow pointing outwards from the
inflator (SEE FIGURE 1 ON PAGE 9).
3.
Connect the hose to the inflation valve of the inflatable unit using the fittings supplied. It is
important to choose the right fitting for the valve and to check that no air leaks are detected.
Make sure that there are no kinks, obstructions or leaks in the air path.
4.
Set the pressure knob to the value recommended by the inflatable unit manufacturer.
5.
Start inflating by pressing the power button (SEE FIGURE 1 ON PAGE 9).
6.
The inflator will automatically stop when the set pressure is reached.
WARNING, IN THE EVENT OF OVERHEATING DUE TO AN EXTENDED USE, THE INFLATOR WILL STOP
AUTOMATICALLY TO AVOID DAMAGE TO ITS COMPONENTS.
TAKE INTO ACCOUNT THE MAXIMUM AND SUITABLE INFLATION PRESSURE OF THE INFLATABLE
UNIT. ALWAYS SET THE MAXIMUM RECOMMENDED PRESSURE USING THE PRESSURE SETTING
12
KNOB. DO NOT OVER INFLATE.
9. TO DEFLATE
1.
Connect the hose to the suction port, in the direction of the arrow pointing inwards from the inflator
(SEE FIGURE 1 ON PAGE 9).
2. Connect the hose to the inflatable unit valve using the fittings supplied. It is important to choose
the right fitting for the valve and to check that no air leaks are detected. Make sure that there
are no kinks, obstructions or leaks in the air path.
3.
Start deflating by pressing the power button (SEE FIGURE 1 ON PAGE 9).
4.
The inflator stops automatically when a pressure of -40/-50 mbar is reached. However, deflation
can be stopped by pressing the shutdown button (SEE FIGURE 1 ON PAGE 9).
THE INFLATOR CAN BE DAMAGED BY SAND, DUST OR WATER GETTING INSIDE THE INLET PORT. THIS
WILL CAUSE OVERHEATING AND WILL DAMAGE THE TURBINE. SHOULD THIS BE THE CASE, IMMEDIATELY
SWITCH THE INFLATOR OFF.

10. TROUBLESHOOTING

POSSIBLE CAUSE
PROBLEM
Cable not connected properly.
The inflator does
Battery not charged (GE10-B only)
not start
Damaged cable.
The inflator does
Hose wrong connection.
not inflate/deflate
Low pressure
Possible electronic fault.
10.1 ACCESSORIES
The recommended accessories when using the inflator are the original SCOPREGA ones.
The use of any accessory not recommended for this inflator can be dangerous.
11. LED DIAGNOSTICS FOR BATTERY STATUS,
TEMPERATURE AND BATTERY CHARGER ALARM
LED
MEANING
OFF
OFF
Flashing GREEN
Standby - CHARGED battery
Batterie en charge
YELLOW
Standby - 50% battery
Flashing ORANGE
Flashing fast ORANGE
Standby - Battery running low
Standby - LOW battery
Steady ORANGE
Steady ORANGE (5 seconds of
Low battery voltage
operation)
Overtemperature inside the
Steady RED
pump
WARNING
The inflator should not operate while the battery is being charged. The battery power
supply unit only works if the inflator is not operated.
POSSIBLE SOLUTION
Connect the cable.
Check the battery.
Contact a SCOPREGA service
centre.
Connect the air hose to the
correct port.
Contact a SCOPREGA service
centre.
STATUS
We recommend you to charge the battery
before operating.
The inflator does not start
The inflator goes OFF
The inflator goes OFF