1. Introduction
To all residents of the European Union
Important environmental information about this product
This symbol on the device or the package indicates that disposal of the device after its lifecycle could harm the environment.
Do not dispose of the unit (or batteries) as unsorted municipal waste; it should be taken to a specialized company for recycling.
This device should be returned to your distributor or to a local recycling service.
Respect the local environmental rules.
If in doubt, contact your local waste disposal authorities.
Thank you for choosing Velleman! Please read the manual thoroughly before bringing this device into service. If the device was damaged in
transit, do not install or use it and contact your dealer.

2. Technical Specifications

Capacity
Display Resolution
Counting Range
Tare Range
Zero Range
Min. Input Piece Weight
Operating Temperature
Power Supply
Power Consumption
Dimensions
Spare PSU
Spare Battery
Unit Conversion
3. Setting up Your Scales
Place the scales on a stable and horizontal surface where it is out of the sunlight and protected against extreme temperatures and
temperature changes, humidity, fumes, dust, draughts and electromagnetic fields. Turn the adjustable feet until the scales are level.
Insert the battery into the scales minding the polarity. Connect the scales to the PSU and insert the PSU into the mains.

4. Operation

4.1. Key Description
VTBAL6_v3
VTBAL6 – COUNTING SCALES
5kg/12lb
6.0000kg x 0.0005kg/13.2280lb x 0.0010lb
0 ~ 16777216
0 ~ 100% FS
power-on zero range ± 5% FS
0.5g/0.0002lb
15°C ~ 35°C
220VAC/12VDC PSU + internal 6V/4Ah rechargeable battery (both incl.)
< 120mA at lowest brightness setting (200mA at default setting)
110 x 290 x 330mm
order code PS1205R
order code WP4-6
1lb = 0.45359237kg, 1kg = 2.20462262lb
Numeric keypad
Clear the entered data (in input mode) or exit input mode after
clearing data
Confirm and save the entered data (in input mode) or confirm
operation (all other modes)
Zero the scales – range is power-on zero point ± 5% - proper
power-on zero point is calibration zero point ± 10% of FS
Tare function – tare range is 0 ~ 100% of FS
Totalising function
Choose the current weighing unit (kg or lb) or piece weighing unit
(g or lb)
Input the piece weight
Input the upper limit
Input the lower limit
On/off key or exit key when in auto off setting mode and calibration