Video Intercom Two-Wire Bundle
Two-Wire Villa Door Staton
E N G L I S H
Appearance
1
1
2
3
Speaking Indicator
Microphone
Calling Indicator
4
Open Door Indicator
5
Built-in Camera
6
Supplement Light
7
Loudspeaker
8
TAMPER
9
Call Buton
2
Terminals
A1
NC1 : Normally Close
A7
AIN2 : Alarm Input 2
A2
A8
AIN1 : Alarm Input 1
NO1 : Normally Open
A3
A9
12V OUT : Power Output for Lock
COM : Common Interface
A4
A
NC2 : Normally Close
10
GND : Grounding
NO2 : Normally Open
A5
A
11
2-WIRE: Wire to Indoor Staton
A6
GND : Grounding
Installaton
3
To install the door staton onto the wall, you are required to utlize a matched gang box.
The dimension of gang box is shown.
The door staton supports surface mountng and flush mountng.
Before you begin:
1. Make sure the device in the package is in good conditon and all the assembly parts
are included.
2. Make sure all the related equipment is power-off during the installaton.
3. Check the product specificaton for the installaton environment.
4. Connect cables to the door staton before mountng.
Surface Mountng with Gang Box
1. Take the gang box and screws from the packing box.
2. Fix the gang box onto the wall with 4 screws.
3. Install the door staton into the gang box, and fix it with 4 screws.
Flush Mountng with Gang Box
1. Cave the installaton hole, and pull the cable out.
Note: The suggested dimension of the installaton hole is 103.5 mm × 162.5 mm × 40.5
mm.
2. Insert the gang box into the hole with 4 screws.
3. Install the door staton into the gang box, and fix it with 4 screws.
Getng Started
4
Wire the door staton to the indoor staton with 2-wire cables.
You can actvate the door staton by indoor staton.
Set the open duraton and other parameters by indoor staton.
Refers to the Indoor Staton Configuraton Guide for details.
The applicaton of the device is shown.
Video Intercom Operaton
5
You can call the resident by pressing the call buton.
1. Press the call buton of the door staton.
2. The resident can receive/decline the video call, unlock the door, etc.
Note:
When the video intercom between you and the resident is realized, you can speak to the
resident, and the live view of door staton will be displayed on the connected indoor
staton.
When the door staton is calling the resident, the door staton will detect the brightness
of video automatcally. When the brightness is lower than the expected threshold, the
supplement light will be enabled.
When the supplement light is enabled, the backlight of key will be auto-enabled,
otherwise, the door staton will detect the brightness of live view and enable the backlight
of key when the brightness of live view is lower than expected threshold.
FCC Information
Please take atenton that changes or modificaton not expressly approved by the party responsible for
compliance could void the user's authority to operate the equipment.
FCC compliance: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protecton against
harmful interference in a residental installaton. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instructons, may cause harmful
interference to radio communicatons. However, there is no guarantee that interference will not occur in a
partcular installaton. If this equipment does cause harmful interference to radio or television recepton, which
can be determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separaton between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for help.
This equipment should be installed and operated with a minimum distance 20cm between the radiator and
your body.
Please take atenton that changes or modificaton not expressly approved by the party responsible for
compliance could void the user's authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operaton is subject to the following two conditons:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired
operaton.
This equipment complies with FCC radiaton exposure limits set forth for an uncontrolled environment. This
equipment should be installed and operated with minimum distance 20cm between the radiator & your body.
FCC Conditions
This device complies with part 15 of the FCC Rules. Operaton is subject to the following two conditons:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause undesired
operaton.
EU Conformity Statement
This product and - if applicable - the supplied accessories too are marked with "CE" and
comply therefore with the applicable harmonized European standards listed under the RE
Directve 2014/53/EU, the EMC Directve 2014/30/EU, the RoHS Directve 2011/65/EU.
2006/66/EC (batery directve): This product contains a batery that cannot be disposed of as
unsorted municipal waste in the European Union. See the product documentaton for
specific batery informaton. The batery is marked with this symbol, which may include
letering to indicate cadmium (Cd), lead (Pb), or mercury (Hg). For proper recycling, return
the batery to your supplier or to a designated collecton point. For more informaton see:
www.recyclethis.info
2012/19/EU (WEEE directve): Products marked with this symbol cannot be disposed of as
unsorted municipal waste in the European Union. For proper recycling, return this product to
your local supplier upon the purchase of equivalent new equipment, or dispose of it at
designated collecton points. For more informaton see: www.recyclethis.info
1
UD17635N-A
1
2
3
4
3
103
83
3
3
Screws
Door Station
5
6
7
8
9
4
40
Power Supply
Unit:mm
1
2
Screws
Junction Box
Wall
2
A1
NC1 NO1
COM
NC2 NO2 GND
LOCK1
LOCK2
Door Lock
Door Station
3
Screws
Door Station
Screws
A11
AIN2 AIN1
12V
GND
2-WIRE
OUT
ALARM IN
LOCK POWER
Indoor Station
APP Control
Multicore cable
2-wire cable
Internet
Power Supply
Wi-Fi
1
2
Gang Box
Wall