Herunterladen Inhalt Inhalt Diese Seite drucken

Parts List; Operation - Lacor 61700 Gebrauchs- Und Instandhaltungsanleitung

Elektronischeküchenwaage mit rechteckig oberteil
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 23
Be sure you've received all parts:
- Weighing platform and connecting cable
- Stainless steel tube
- Revolving support
- Electronic headstock
- Electrical supply cable
- Allen key and 2 screws
1.- Place the platform in a horizontal position. Pay attention to the levelling window, and
regulate the height of the feet by turning them if necessary.
2.- Cross the connection cable that is mounted on the platform across the inside of the
stainless steel tube. Place the end of the stainless steel tube in its casing on the platform.
3.- Run the end of the connection cable through the revolving support. Place the revolving
support in the end of the tube. Use a screwdriver to fasten the support to the end of the
stainless steel tube.
4.- Place the electronic head on the revolving support. Connect the connection cable to the
back of the electronic head.
5.- Use the Allen wrench (socket head cap wrench) and two screwdrivers to firmly attach the
base to the stainless steel tube.
7.- Turn on the weighing machine.
"auto- switch off function":
1.- Press and hold [CHANGE] key and switch on the scale at the same time. Do not
release your hand from [CHANGE] key till WEIGHT LCD shows the version of scale
(6.3).
2.- Press and hold [zero] key till WEIGHT LCD shows SEtUP.
3.- Press [3] [2] key once, WEIGHT LCD will show OFF, 5 ,15 , 30.
4.- Press [CE] key then you can choose the auto-switch off time, or turn off this function.
5.- Press and hold [CHANGE] key, WEIGHT LCD will flash good , and the scale will re-boot
automatically. Finish setting.
Carry out calibration of the same using calibration instructions.
38

PARTS LIST

OPERATION

4
3
2
1

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis