Selecting a working position
THE ACE is constructed so that it can work in several position. Every position uses a different angle in
order to immediately direct the air flow to where it is required for effective drying. The arrow at the side
of the unit shows the direction of air flow.
Vertical - Place the ACE on the feet (put handle sideways) which are a longer way from each other in
order to let the ventilation air flow in parallel through the room.
(1) Front side down- Place the ACE on all four feet, with the grid facing downward on the switch side.
In this position, air is directed downward to the floor for targeted drying.
(2) Tilted back- Place the ACE on the narrow feet (handle on top). Tip the ACE back until the unit sits
at an angle on the bottom feet. In this position, air is directed upward for drying parts which are located
higher.
(3) Stacked operation- Place one ACE Turbo Ventilator on a solid, even surface onto the feet which
are a longer way from each other (handle sideways). Put a second ACE Turbo Ventilator onto it so
that its rubber feet sit in the dents on the lower unit. When stacking units on each other, exercise
caution in order to avoid injuries due to units falling down.
(4) Tilted forward- Place the ACE onto the narrow feet (handle of top). Tip the ACE forward until the
unit sits at an angle on the bottom feet. In this position, air flows in parallel to the bottom of the unit.
(5) Front side up- Place the ACE on all four feet, with the grid facing upward on the switch side. In this
position, air is immediately directed upward in order to dry the ceiling, for example.
(6) Stack for storage- ACE Turbo Ventilator mesh together so that it is easy to store and transport
them. Set up the units, with the grids facing each other. Turn the units a bit until the feet are not in line
any more.
1
2
3
4
5
6
Humidity control
If Turbo fans are used in order to increase evaporation in a building, air humidity will normally
immediately increase too. It is therefore advisable to use Turbo fans together with condensation
dryers. In order to control the development of mould, air humidity in rooms has to be kept below 60 per
cent. If possible, air humidity should be around 50%. A HEYLO dehumidifier can be used for the
purpose.
In order to improve drying, the area to be dried has to be closed off from the rest of the building. Set
the heating or the air conditioning to 20 to 27 deg. C. If condensation dryers are not available, exhaust
fans should be used on attics, in kitchens and bathrooms in order to remove humidity. If the outside air
is very dry, windows or doors may be opened a bit.
EN
9