Herunterladen Diese Seite drucken

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

EN

Troubleshooting

Malfunction
Cause
Pressure
Dirty filter bed
gauge
has
reading over
1 bar
Pressure
is
Hair and lint strainer
too low
basket is dirty; Pump
gets too little water
Air
in
the
Poor seal on the in-
pump
take
side
of
pump.
Leaking filter
Seal Defective
Pump
does
Not plugged in
not run
G.F.C.I/ or main cir-
cuit breaker tripped
Pump motor defec-
tive
Sand in Pool
If the sand is newly
replaced, the under-
sized grains are still
present
Sand
in
Central
Valve (from back-
wash)
Separation wall in fil-
ter is improperly in-
stalled
Filter bottom strainer
is damaged
Air in system
Solution
Backwash the filter (posi-
tion 4)
Clean the hair and lint
strainer; check the suc-
tion line and the water
level
Tighten hose clamps and
the
connecting fittings.
Check the seal, replace if
needed
Check the socket and
power cord
Switch on the breaker (if
it is immediately tripped
again, there is a defect in
pump or controls)
Replace the entire pump
Backwash several times
until the backwash water
is clear (position 4)
Purge into drainpipe for
30 seconds (position 6)
Check
the
separation
wall for proper position-
ing
Replace the filter bottom
strainer
Loosen, but do not re-
move, the transparency
cover on the filter tank to
allow any trapped air to
escape.
Tighten
the
cover once all of the air
has escaped
Page 11 of 22