User's guide

Introduction
Energy saving
Control panel
Manual Bypass
Mode
Automatic Demand
Mode
Manual Operation
Mode
Fireplace Mode
32
This section only describes how the different functions are activated and operated.
For further information regarding each individual function please see the section
"Functional description", on page 27 or the section "Set points and control strategies" in
the installation guide.
Energy saving turns off all control panel lights – except the green light-emitting diode –
after two minutes if the unit is not activated.
This is the control panel which is delivered with every unit. See a description of each
button below:
Push this button to active Manual Bypass.
When bypass is activated the button will be alight. Bypass is only active for six hours
after which the unit will switch to Automatic Bypass Mode.
Push this button to activate Automatic Demand mode of the air volume. When Auto-
matic Demand Mode is active both the button and the amount of light-emitting diodes
matching the fan steps alight.
Push this button to activate Manual Operation Mode.
Fan Step 0-4 is chosen by repeatedly pushing the manual operation button. If the unit
needs to be stopped the button must be activated until all four fan step buttons are off.
The unit and Fan Step 4 is off for four hours after which it returns to Manual Operation
Mode, Fan Step 3.
Press for 6 seconds until Fan Step 3 flashes on the control panel. The unit stops ex-
tracting air and will maintain supplying air on Fan Step 3 for 15 minutes.