Herunterladen Inhalt Inhalt Diese Seite drucken

Where To Use; Handling And Transport - Sanity SANY-MED-80 Bedienungsanleitung

Ozongenerator zur desinfektion von umgebungen
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 16
INSTALLING, HANDLING, STARTING AND

2.1. WHERE TO USE

Air purification and sanitation of the surfaces in small and medium size rooms up
to a max. of 80 m
3
1.
Connect the power lead supplied with the unit (on the right hand side) to
the power socket.
2.
Turn on the ON-OFF switch to pos. 1
3.
Select the program (1SHORT – 2 MEDIUM – 3 LONG)
4.
Press the START button to begin the sanitation program (the red LED
remains alight throughout the treatment)
5.
When the sanitation cycle is complete, the unit turns off automatically but
remains powered, turn the ON-OFF switch to pos. 0 to turn it off completely.
2.2. PROGRAMMING
PROG. 1 SHORT
PROG. 2 MEDIUM ROOM (up to 50 m
PROG. 3 LONG
N.B. These recommended times may vary in the case of very old interiors or
precarious hygienic situations, and therefore the cycle duration should be increased.
N.B. Never enter the site being treated during the function cycle, and if possible
aerate the rooms before using them.
Attention: inhaling high concentrations of ozone and over a long time can
irritate the nose and throat. Keep the unit out of the reach of children.

2.3. HANDLING AND TRANSPORT

The unit must be handled with care, avoiding knocks that could damage the internal
components.
It should be carried in its own special case.
2.4 WORKING AND STORAGE CONDITIONS
The unit must be used inside with a room temperature between +4 and +40° C and
a maximum relative humidity of 90%.
2.5. CONNECTION TO THE POWER SUPPLY
After positioning the unit, connect the supplied power lead to the power socket.
Ensure that the power socket is protected upstream by an automatic circuit breaker
switch.
12
- SECTION 2 -
PROGRAMMING THE UNIT
.
Mounting and starting instructions
ROOM (up to 20 m
ROOM (up to 80 m
)
DURATION 34 MIN.
3
)
DURATION 50 MIN.
3
)
DURATION 90 MIN.
3

Werbung

Inhaltsverzeichnis
loading

Verwandte Produkte für Sanity SANY-MED-80