Technical Data

Output voltage
Output current
Display resolution
Display accuracy "V"
Display accuracy "A"
Max. output power
Residual ripple (p-p)
Control response at
Change of load 10~90%
Control response at
Mains change 10%
Output USB AUX 1
Output USB AUX 2
Mains fuse
5x 20 mm fine fuse
Operating temperature
Rel. Humidity
Max. operating altitude
Pollution degree
Operating voltage
Power consumption max.
Protection class
Power factor (active PFC)
Degree of effectiveness
Unit' cooling system
Dimensions (W x H x D)
Weight
LVD Directive 2006/95/EC
All manuals and user guides at all-guides.com
TOPS-3205
TOPS-3363
1 - 20 V/DC
1 - 36 V/DC
0.25 – 5 A
0.25 – 3 A
0.01 V / 0.001 A
< 5 V: ±0.05 V
≥ 5 V: ±(0,2% + 0.05 V)
≤ 1 A: ±0.015 A
> 1 A: ±(0,5% + 0.006 A)
100 W
<120 mV
<150 mV
70 mV
50 mA
25 mV
20 mA
5 V/DC, max. 1.8 A
5 V/DC, max. 1.8 A
T2A/250 V time lag
+5 °C to +40 °C
max. 85%, non-condensing
2000 m above sea level
2
100 - 240 V AC, 50/60 Hz
1.6 A (at 230 V ca. 0.83 A)
1
>0.9
≥80.5 %
Convection
70 x 150 x 250 (mm)
2 kg
EN 61010
TOPS-3602
1 - 60 V/DC
0.25 – 1.6 A
<180 mV
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in
electronic data processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited.
This publication represent the technical status at the time of printing.
Copyright 2016 by Conrad Electronic SE.
*1433327_28_29_V2_0616_02_VTP_m_en

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Tops-3205Tops-3363143332714333281433329

Inhaltsverzeichnis