Operating instructions
TOPS-3602 100 Watt Laboratory Power Supply
Item no. 1433327
TOPS-3205
Item no. 1433328
TOPS-3363
Item no. 1433329
TOPS-3602
Intended Use
The laboratory power supply unit serves as a potential-free DC voltage source to operate low-voltage loads.
The connection is made at the front side via 4 mm safety sockets. In addition, two independent power USB
charging outputs are available.
Adequately dimensioned connecting cables must always be used. A wire cross-section
that is too small can cause overheating and fire.
The output data of the laboratory power packs is as follows:
Type
Output voltage
TOPS-3205
1 - 20 V/DC
TOPS-3363
1 - 36 V/DC
TOPS-3602
1 - 60 V/DC
Voltage and current adjustments are continuous via digital control button. By pressing on the control button
you can change from coarse to fine adjustment. This makes a quick and precise adjustment of values pos-
sible. Values are displayed on a high-contrast LED display. The current limit for the constant current mode
can be preset without shorting.
The device is overload and short-circuit-proof and contains a safety temperature cut-off. The DC output is
also overvoltage protected (OVP).
The design of the product complies with the safety class 1. Only supply the product with a voltage from an
earthed standard mains socket connected to the public supply grid. The mains socket must be near the
device and easily accessible, or an emergency stop device must be present.
Do not interconnect the outputs of multiple power packs. This can result in hazardous contact voltages or in
damage to the unit.
Operation in potentially explosive atmospheres (Ex) or wet areas or under adverse environmental conditions
is forbidden. Adverse environmental conditions are:
• Damp or excess air humidity
• Dust and flammable gases, vapours or solvents
• Thunderstorms or similar conditions such as strong electrostatic fields, etc.
Any use other than that described above can lead to damage to the product and may involve additional risks
such as short circuits, fire, electric shock, etc. No part of the product may be modified or converted!
The safety instructions are to be observed without fail!
Explanation of symbols
An exclamation mark in a triangle refers to important information in these operating instructions
that must be adhered to.
The product is CE compliant and meets the requirements of the current European and national
guidelines.
Connection terminal for the internal protective earth; this screw/contact must not be removed.
Ground potential, reference mass
Only to be used in dry indoor areas.
Safety Instructions
Please read the entire manual before using the device as it contains important information
for proper operation.
The warranty will be void in the event of damage caused by failure to observe these safety
instructions! We do not assume any liability for any resulting damage!
We do not accept liability for damage to property or personal injury caused by incorrect
handling or non-compliance with the safety instructions! In such cases, the warranty will
be null and void.
• This device has left our factory premises in a safe and perfect condition.
• We kindly request the user to observe the safety instructions and warnings contained in the
enclosed operating instructions so this condition is maintained and to ensure safe operation.
• The unauthorized conversion and/or modification of the product is inadmissible for reasons
of safety and approval (CE).
• If you have doubts about how the device should be operated or how to connect it safely,
consult a trained technician.
• The device must not be opened. Live parts may be exposed, if you open covers or remove
parts – unless you can do this by hand. Capacitors inside the device may still be charged,
even if the device has been disconnected from all voltage sources.
• Observe the safety and operating instructions of any other devices you intend to connect
to the device, in addition to those contained in the individual chapters of these operating
instructions.
• Never touch the device with wet or moist hands. There is danger of a life-threatening electric
shock.
All manuals and user guides at all-guides.com
Output current
USB AUX 1
0.25 – 5 A
5 V/DC 1.8 A
0.25 – 3 A
5 V/DC 1.8 A
0.25 – 1.6 A
5 V/DC 1.8 A
• Do not leave mains power supplies and connected consumer devices in operation unatten-
ded.
• Only use fuses of the rated type and current. It is absolutely prohibited to use repaired fuses.
• Do not use non-insulated metallic leads.
• Keep the unit out of the reach of children. It is not a toy.
• On industrial sites, the accident prevention regulations of the association of the industrial
workers' society for electrical equipment and utilities must be followed.
• Power supply units used in schools, training facilities, do-it-yourself and hobby workshops
should not be handled unless supervised by trained, responsible personnel.
• The device will become warm during operation. Ensure sufficient ventilation of the device.
Do not cover or seal the ventilation apertures of the device. Make sure there is enough free
space on the sides.
• The base of the unit could chemically react considering the large variety of protection products
for furniture. Place the device on a resistant, smooth and flat surface.
• If a safe operation can no longer be assumed, the device must be put out of operation and
secured against unintended operation. Safe operation can no longer be assumed if:
- the unit exhibits visible damage,
- does not function any longer and
- the unit was stored under unfavourable conditions for a long period of time or
- it has been subjected to considerable stress in transit.
USB AUX 2
• You should also heed the additional safety instructions in each chapter of the operating inst-
ructions for the connected devices.
5 V/DC 1.8 A
• Never switch the device on immediately after taking it from the cold into a warm environment.
5 V/DC 1.8 A
Condensation that forms might destroy your device under unfavourable conditions. Allow the
5 V/DC 1.8 A
device to reach room temperature before switching it on.
• Do not place any vessels with liquids on the device.
• The power supply unit is not designed for attaching to humans or animals.
Package Contents
• Laboratory power supply unit
• 1 pair of test leads with alligator clips
• Power cable
• Operating Instructions
Control Elements
1
Display
2
Button for switching the DC outputs on and off
3
4 mm safety socket „earth potential" (mass)
4
4 mm safety socket „negative pole" (-)
5
4 mm safety socket „positive pole" (+)
6
Controls to adjust output voltage, „VOLTAGE"
7
Controls to adjust output „CURRENT"
8
High-power USB output 1
9
High-power USB output 2
10 Mains fuse holder (rear)
11 Earthed non-heating connection (mains connection), IEC 320 C14
12 Eyelet to prevent theft, e.g., by cable lock
13 Power switch for switching the device on (1=ON / 0=OFF)
14 Carrying handle
Explanation of symbols
V
A
C.V.
C.C.
AUX.1
AUX.2
OUTPUT
displays electrical voltage
displays electrical current
display in constant voltage mode (normal mode)
display with active current limit (constant current mode)
USB power output 1
USB power output 2
(ON, OFF)
Control indicator for disabled output