6.1.4 Start-up checklist
Work
Action
steps
1
Read operating manual.
2
Check the voltage supply and compare with the values on the type label.
3
Check the grounding system (by measurment).
4
Check the mechanical connection to the water supply system. Tighten the flanges and the screws.
5
Fill and ventilate the compact booster unit from the input side.
6
Check the refilling.
7
Check the switching device to see if all electrical lines are still securely plugged into the clamps.
8
Check the preset value, correct if necessary.
9
Check if the dry running protection is functioning. If not available, note in start-up protocol.
10
Venting the pump a second time, after it has been running for a few minutes (5 to 10).
11
Check the precharge pressure
12
Fill out the start-up protocol with the operator and show the operator how the machine functions.
6.2 Limits of operating range
DANGER!
Exceeding the limits
Damage to the pump unit!
Observe the operating data specified in the data
sheet.
Avoid operation against closed shut-off valve.
Never operate the pump set outside the limits
specified below.
DANGER!
Risk of explosion!
Exceeding the limit of use regarding to the pumped
medium.
Never pump different fluids that can chemically react
with each other.
Never pump a flammable medium with a medium
temperature above the ignition temperature.
CAUTION!
Excessive temperature difference between medium
and pump
Damage of the machine!
The temperature difference between medium and
pump must never exceed 60 ° C.
In cases where the temperature difference between
the pump and the medium is higher than 30 ° C,
slowly fill / warm the pump to avoid the risk of a
temperature shock.
The operating range depends on the application and a
combination of pressure and temperature.
GB

6.2.1 Environmental conditions

Keep parts in their original packaging and unpack them
shortly before use.
The following parameters apply during transportation and
storage:
Parameter
Environment:
Min. ambient temperature:
Max. ambient temperature:
CBU142 (ON/OFF)
CBU142FU
Max. ambient relative
humidity:
*non condensing

6.2.2 Max. operating pressure

CAUTION!
Exceeding the permissible operating pressure.
Damage to seals and connections!
Do not exceed the operating pressure in the data
sheet.
6.2.3 Pumped medium
Industrial water
Cooling water
Liquids which do not attack the materials chemically
and mechanically.
10
finished
Value
clean, dry and dust free
0 °C
+40 °C
+30 °C
85 % *