1
EN
Connectors – external power supply
Example:
Signal X9
Pin
12
11
10
9
8
7
6
5
4
3
2
1
+ -
Inputs
External 24 V power supply for the controller.
Pin 11 and 23 (common GND) serve as a "return line"
for the outputs.
The GND for the external 24 V power supply must be
used as the return line for Pin 11 and 23.
12
I/O
Name
Supply GND Int.
Supply GND I/O
Output
O3
Output
O2
Output
O1
Output
O0 (linking OK), e.g.
Input
I3 (tool start), e.g.
Input
I2
Input
I1
Input
I0
Supply +24 V O
Supply +24 V Int.
P2300HW | 2019-08
Signal X10
Pin
I/O
24
23
22
Output
21
Output
20
Output
19
Output
18
Input
17
Input
16
Input
15
Input
14
13
Outputs
External 24 V power supply for the controller.
Pin 2 and 14 (common output) are the voltage source
for the inputs.
Pin 2 and 14 must be connected to the external 24 V
power supply.
Name
Supply GND Int.
Supply GND I/O
O3
O2
O1
O0 (linking OK), e.g.
I3 (tool start), e.g.
I2
I1
I0
Supply +24 V O
Supply +24 V Int.