EN
Hazards due to hydraulic and pneumatic energy
Depending on the version, the product works with high hydraulic or pneumatic
pressure (see technical data). Sections of the system that need to be opened, such
as pressure lines, valves or loads, have to be de-pressurised before the start of
repairs. No residual pressure is permitted to remain.
Hazard due to electrical voltage
Contact with live components may cause death.
Turn off the energy supply and secure it against reconnection prior to
assembly, adjustment and maintenance tasks.
The electrical connection may only be established by a licensed electrician.
Live components have to be covered.
Hazards due to lubricants
The safety notices and instructions of the lubricant manufacturer have to be observed
and followed. The manufacturer of this product assumes no liability whatsoever for
incidents caused the failure to observe the provisions, instructions and
recommendations of the lubricant manufacturer.
Due to the rotating process, lubricant can be hurled into the eyes.
Take appropriate protection and provide personal protective equipment.
USE EYE PROTECTION
Information on the use of safety goggles
Hazards due rotating work pieces
There is a risk of injury because of the open rotating shaft.
A protective housing is mandatory.
On contact shut down the servomotor.
CAUTION
The product always has to be shut off prior to all work.
Maintenance, upkeep and troubleshooting
Prescribed adjustment and maintenance tasks according to the maintenance
schedule have to be carried out in a timely manner.
Inform the operating personnel about adjustment and maintenance task.
The master switch (if any) has to be turned off.
Disconnect the energy supply from the network and secure it against
unintentional reconnection.
Pneumatic and/or hydraulic systems must be de-pressurised.
Check all threaded connections and fittings for tightness.