Herunterladen Inhalt Inhalt Diese Seite drucken

STAMOS S-LS-15 Basic Bedienungsanleitung Seite 8

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
BEFORE FIRST USE
Upon receipt of the goods, check the packaging for integrity and open it. If the packaging is damaged, please
contact your transport company and distributor within 3 days, and document the damages as detailed as
possible. Do not turn the package upside down! When transporting the package, please ensure that it is
kept horizontal and stable. Please keep all packaging materials (cardboard, plastic tapes and styrofoam), so
that in case of a problem, the device can be sent back to the service centre in accurate condition.
Disposing of packaging
The various items used for packaging (cardboard, plastic straps, polyurethane foam) should be conserved,
so that the device can be sent back to the service centre in the best condition in case of any problems!
INSTALLING THE APPLIANCE
Appliance location
The work surface where the device will be located must be suitable for the size of the appliance, please re-
fer to the measurements. The work surface must be levelled, dry, heat-resistant and at a fitting height from
the ground to enable a proper use of the device.
The power cord connected to the appliance must be properly grounded and correspond to the technical
details.
INFRARED LAMP
1.
Device must be placed on stable work table.
2.
Connect the device to the power source.
3.
Turn on the device with the main switch placed at the back of the device, turn on the infrared lamp with
switch (1).
4.
Temperature setting: using buttons (4) set the desired temperature. Displays (2) and (3) will show the
infrared lamp temperature and external sensor temperature.
5.
After work, turn off the infrared lamp by switch (1).
7.
If the device is not being used for a long time, it should be completely disconnected from the power
source.
SMD REWORK STATION
1.
Device must be placed on stable work table, SMD rework gun must be placed into the holder.
2.
Fix the appropriate nozzle and connect the device to the power source.
3.
Turn on the device with the main switch placed at the back of the device, turn on the SMD rework gun
with switch (11), gun will start to heat.
4.
Temperature setting: using buttons (13) set the desired temperature. Temperature will be shown on the
display (12).
5.
Airflow volume adjustment: set the desired airflow volume using knob (14).
6.
After work, the SMD rework gun should be placed into the holder. Turn off the SMD rework by switch
(11).
7.
If the device is not being used for a long time, it should be completely disconnected from the power
source.
8.
NOTE: It is forbidden to cover the air intake holes on the handle of a SMD rework gun during work.
This may cause serious damages of the fan and the heater!
14
EN
SOLDERING IRON OPERATION
1.
Device must be placed on stable work table, soldering iron must be placed into the holder.
2.
Fix the appropriate soldering tip and connect the device to the power source.
3.
Turn on the device with the main switch placed at the back of the device, turn on the soldering iron
with switch (8), it will start to heat.
4.
Temperature setting: using buttons (10) set the desired temperature. Temperature will be shown on the
display (9).
5.
After work, the soldering iron should be placed into the holder. Turn off the soldering station by switch
(8).
6.
If the device is not used for a long time, it should be completely disconnected from the power source.
PREHEATER OPERATION
1.
Device must be placed on stable work table.
2.
Connect the device to the power source.
3.
Turn on the device with the main switch placed at the back of the device, turn on the preheater plate
with switch (5), it will start to heat.
4.
Temperature setting: using buttons (7) set the desired temperature. Temperature will be shown on the
display (6).
5.
After work, turn off the preheating plate by switch (5).
6.
If the device is not used for a long time, it should be completely disconnected from the power source.
CHANGING THE TEMPERATURE DISPLAY UNITS
⁰F – Fahrenheit)
Switch (6) is designed for changing the temperature units between Celsius and Fahrenheit (⁰C – Celsius,
TEMPERATURE COMPENSATION
Compensation temperature setting procedure:
For the soldering iron / SMD rework / preheating plate: turn on the devices, and then press and hold
both temperature setting buttons for about 3 seconds. Display will show "00". Using appropriate
buttons (7) / (10) / (13) set the desired temperature compensation for each of the devices (-50 °C ~
+50 °C.). After setting the temperature compensation, do not press any button for about 3 seconds –
device will save changes and will go into work mode.
Setting the power compensation of the infrared lamp: turn off the infrared lamp, press and hold both
temperature setting buttons, then turn on the infrared lamp and wait until display will show "20".
Release the buttons and set the compensation value.
Setting the temperature compensation of the external sensor: turn on the infrared lamp, then press
and hold both temperature setting buttons for about 3 seconds. Display will show "00". Release
the buttons and set the compensation value (-50 °C ~ +50 °C.). After setting the temperature
compensation, do not press any button for about 3 seconds – device will save changes and will go
into work mode.
EN
DE
15

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis