Herunterladen Diese Seite drucken

Technical Data; Wall Mounting - Bosch GAL 18V-40 Professional Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für GAL 18V-40 Professional:

Werbung

Technical Data

Charger
Article number
Battery charging voltage
(automatic voltage detec-
tion)
Charge current
Permitted charging temper-
ature range
Charge time at battery capa-
city, approx.
– 2.0 Ah
– 3.0 Ah
– 4.0 Ah
– 5.0 Ah
– 6.0 Ah
Number of battery cells
Weight according to
EPTA-Procedure 01:2014
Protection class
Operation
Start-up
Note the mains voltage! The voltage of the power source
u
must match the voltage specified on the rating plate of
the charger. Chargers marked with 230 V can also be op-
erated with 220 V.
Charging process
The charging process begins as soon as the mains plug for
the charger is inserted into the mains socket and the battery
(1) is inserted into the charging slot (2).
Thanks to the intelligent charging process, the charge condi-
tion of the battery is automatically detected and then
charged up with the optimal charge current depending on
battery temperature and voltage.
In this way, the battery is treated with care and remains per-
manently fully charged when it is stored in the charger.
What the display elements mean
Flashing green battery charge level indicator (4)
The rapid-charging procedure is indicated by
flashing of the green battery charge level in-
dicator (4). The battery can be removed at any
time and used.
Note: The charging process is only possible when the tem-
perature of the battery is within the permitted charging tem-
perature range, see section "Technical data".
Bosch Power Tools
80 %
GAL 18V-40
2 607 226 2..
V
10.8-18
will be completed in the Long Life charging mode.
Continuously illuminated green battery charge level
indicator (4)
A
4.0
°
C
0-45
(80%)/100%
The battery can then be removed for immediate use.
When there is no battery connected, the continuous light of
min
(24)/35
the battery charge level indicator (4) indicates that the
mains plug is plugged into the mains socket and that the
min
(36)/50
charger is ready to be used.
min
(48)/65
Continuously illuminated red battery charge level
min
(60)/70
indicator (3)
min
(72)/95
3-15
kg
0.55
data". The charging process begins as soon as the permitted
/ II
temperature range has been reached.
Flashing red battery charge level indicator (3)
ive measures".

Wall mounting

The charger can be used either free-standing (for use on a
desktop) or mounted on the wall.
When affixing to the wall: Drill two holes, leaving a clearance
as specified in the image.
To secure it, use round-head screws with a diameter of 5 mm
to max. 6.5 mm.
Once approx. 80% of the battery capacity has
been reached, the flashing of the green battery
charge indicator slows down. The rapid-char-
ging process is now completed. If the battery
remains in the charger, the charging process
The continuous light of the green battery
charge level indicator (4) signals that the bat-
tery is fully charged.
The continuous light of the red battery charge
level indicator (3) shows that the temperature
of the battery is outside of the permitted char-
ging temperature range, see section "Technical
The flashing light of the red battery charge
level indicator (3) signals that the charging
process has been interrupted by a different
fault, see section "Errors – causes and correct-
72 mm
1 609 92A 4KU | (12.09.2018)
English | 5

Quicklinks ausblenden:

Werbung

loading