2 in 1 drain pump
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 38
UK
Connect pressure pipe
For occasional use, use a suitable water hose.
The use of rigid pipes with a non-return valve is recommended for use at a fixed location.
This prevents return flow of the liquid when switching off.
• –Screw the pressure hose onto the hose adapte.
All threaded connections must be sealed with thread sealing tape (e. g. Teflon® tape).
• When using a hose, screw a suitable hose adapter onto the hose adapte.
• Push the hose firmly onto the hose adapter and secure with a hose clamp.
Operation
By adjusting the position of sensor switch in support to have different pump starting
water level. This product provides several vertical adjustment positions.
OBS
Do not lift the pump with the cable or pressure hose as these are not designed for
the tensile stress from the weight of the pump.
Installation
The appliance can be put on the pool cover when the base plate is fitted or in the water
container when the base plate is taken off.
The appliance can be submerged under water up to the submerged operating depth men-
tioned in the technical data.
When using as submersible pump, Install the appliance so that the suction openings can-
not be blocked by foreign bodies (place the appliance on a firm, even base if necessary).
Ensure that the appliance is stable.
Submerge the pump at an angle into the liquid to be delivered so that no air pocket forms
on the underside of the appliance. Suction would be prevented by this.
When using as a submersible pump, Leave the pump on the bottom of the liquid container.
Use a strong rope attached to the carrying handle of the pump for lowering.
Tighten the end of the rope firmly after lowering.
32