Herunterladen Diese Seite drucken

HANSGROHE AXOR Starck Organic 80 12006009 Gebrauchsanleitung, Montageanleitung Seite 2

Werbung

EN
0 2
S A F E T Y N O T E S
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.
The hot and cold supplies must be of equal pressures.
I N S T A L L A T I O N I N S T R U C T I O N S
⁄ Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
⁄ The pipes and the fixture must be installed, flushed and
tested as per the applicable standards.
⁄ The plumbing codes applicable in the respective
countries must be observed.
⁄ The drain valve must only be used as intended. It is not
allowed to attach other objects to the drain valve, for
example a semi-pedestal.
⁄ As a standard, the wash basin mixer taps are supplied
with a jet forming device equipped with a handspray
stream. For an alternative jet design, aerator
#98300000 is available as an option.
⁄ When operated in connection with a flow heater, the
fittings must always be opened fully. This ensures
proper function.
T E C H N I C A L D A T A
Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
The product is exclusively designed for drinking water!
S Y M B O L D E S C R I P T I O N
Do not use silicone containing acetic acid!
F A U L T
⁄ Insufficient water
⁄ Mixer stiff
⁄ Mixer dripping
⁄ Instantaneous heater didn't work
A S S E M B L Y (see page 04 )
max. 1 MPa
0,15 - 0,5 MPa
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
max. 70°C
65°C
max. 70°C / 4 min
C A U S E
⁄ Clean filters
⁄ check valve hasn't moved back
⁄ Shut-off unit damaged
⁄ Shut-off unit damaged
⁄ Clean filters
⁄ check valve hasn't moved back
A D J U S T M E N T (see page 06 )
To adjust the hot water limiter. Using a hot water
limiter in combination with a continuous flow
water heater is not recommended.
M A I N T E N A N C E (see page 07)
The check valves must be checked regularly
according to DIN EN 1717 in accordance with
national or regional regulations (at least once a
year).
D I M E N S I O N S (see page 10 )
F L O W D I A G R A M (see page 11 )
 Regular / Normal spray
 Booster
S P A R E P A R T S (see page 14 )
S P E C I A L A C C E S S O R I E S (order as an
extra)
⁄ special tool #58085000 (see page 04 )
⁄ Installation putty (see page 05 )
C L E A N I N G (see page 12 )
O P E R A T I O N (see page 08 )
⁄ Hansgrohe recommends not to use as drinking
water the first half liter of water drawn in the
morning or after a prolonged period of
non-use.
⁄ Adjustable spout:
For the version for right-handers, the spout
remains in the position as supplied to the
customer. For left-handers, the spout can be
turned by 80° to ensure perfect ergonomics.
Simply unscrew the jet forming device with a
suitable wrench and insert the spout in the
different position.
R E M E D Y
⁄ Clean the filter / exchange filter
⁄ Exchange check valves
⁄ Exchange shut-off unit
⁄ Exchange shut-off unit
⁄ Clean the filter / exchange filter
⁄ Exchange check valves

Werbung

loading