12. A/b/C fuNCTIoN ANd CurVE gENErATor

The A/B/C function determines the duration (0 to 600 seconds) for which the respective voltage source A/B/C
remains active before it moves to the next voltage source.
Before setting the A/B/C function first enter the ΔV/Δt value (→ chapter 11 b).
1. Press and hold the mENu (8) button for approx. 3 seconds.
2. Turn the setting controller VoLTAgE (4) until the following display appears:
3. Then press the setting controller VoLTAgE (4) to reach the setting mode.
4. Select the function A, B or C and turn the setting controller CurrENT (5) to set the time period (0 to 600 se-
conds).
Example 1:
Pulse waveform with 3 seconds at 10 V and 1 second at 5 V
• A (PRESET 1) = 5 V
• B (PRESET 2) = 10 V
• FUNC A = 1 second
• FUNC B = 3 seconds
• Δt a-b = 0
• Δt b-a = 0
1. To generate the waveform, press the ShIfT (8) button, then the ΔV/Δt (8) button.
2. The waveform will be periodically generated.
3. To stop generating the waveform press ShIfT (8) button, then the ΔV/Δt (8) button.
1 s
3 s
52
B = 10 V
A = 5 V