products are of low IP rating and should
only be operated in dry areas.
8. Never stick needles or sharp objects (or
the like) in the product!
9. The product should be protected against
mechanical damage by suitable coverings
(e.g. insulation and metal sheeting)
10. In case of additional safety matters a
temperature limiting device may be
installed to protect the application
components from damage.
To prevent danger an RCD or ELCB
has to be installed!
Handling Information:
11. Never lift or pull the heating unit by its
power cord or lead wire.
12. Never handle the heater while in operation.
13. When removing or maintaining the heater,
disconnect the power and allow the heater
to cool down to ambient before handling.
Caution:
To avoid external touching and damage, it is
required that within the application the
product (component) has to be covered by a
metal sheeting or braid, which has to be
included in the protective arrangement of
Protection Class I (protective earth) according
to VDE0100 or to the relevant standards in
your country and is to be taken into
consideration. Metallic components coming in
contact with the product have to be
incorporated in the protection measures of
Protection Class I (protective earth). For
details please refer to the standard VDE 0100
(Germany) or the relevant standards in your
country. Additional to these instructions
special requirements for the specific products
are found on the product label or type plate
and must be followed as well.
The products are designed at a certain
protection class. Considering that the product
is not protected against hazardous body
currents, it has to be installed in such a
manner that any risk is excluded.
In case of doubt or if necessary please contact
us. (see last page for contact information)

Operation

Prior to connection of the product, please
ensure that the supply voltage matches the
product
data
label
specifications
out
documents, respectively.
 Any product must be temperature
controlled! (unless otherwise stated
or specified)
When
connecting
requirements of the standards listed below in
"General Safety Instructions" and "Additional
Safety Instructions" have to be observed. The
maximum
operating
temperature for the product are listed in the
technical data section.
It has to be ensured that this temperature is
never exceeded at any point of the product,
irrespective of whether it is switched on or
off. In cases in which the kind of installation or
application cannot exclude that the maximum
product temperature is exceeded, a suitable
device for temperature control and, if
necessary, for temperature limitation has to
be provided. Proper operation of the
temperature controlling and limiting devices
has to be checked at initial operation.

Maintenance and Safety

Maintenance
and
according to the standards listed under
"General Safety Instructions" and "Additional
Safety Instructions", the regulations of the
employer's liability insurance associations
applicable to the respective way of use, as
well as other relevant rules applying to the
application. The operation of the system
should be checked for correct functionality.
The electrical supply should be checked to
ensure it conforms to the system design
documentation. At least once per year the
function of the temperature controlling and
temperature limiting safety device has to be
checked and the surface and connection line
should be inspected for visible damage.
Warning labels and identification labels should
be clearly visible, intact and able to display the
correct information. Products which show
or
the
product
of
the
accompanied
the
product,
the
and
withstand
Safety
is