Additional switching capacity
XLED PRO ONE S/PLUS S/Max S:
– Incandescent / halogen lamp load:
– Fluorescent lamps, electronic ballasts:
– Fluorescent lamps, uncorrected:
– Fluorescent lamps, series-corrected:
– Fluorescent lamps, parallel-corrected:
– Low-voltage halogen lamps:
– LED lamps < 2 W:
– 2 W < LED lamps < 8 W:
– LED lamps > 8 W:
– Capacitive load:

12. Troubleshooting

Unit without power.
– Fuse not switched ON or faulty.
• Switch ON fuse.
• Change faulty fuse.
– Break in wiring.
• Check wiring with voltage tester.
– Short circuit in mains power supply lead.
• Check connections.
– Any mains switch OFF
• Switch ON mains switch.
– 37 –
1,500 W
430 W
500 VA
900 VA
500 VA
1,500 VA
16 W
64 W
64 W
88 μF