Using the OpenStage M3 Ex / OpenStage
M3 Ex Plus handset in potentially explo-
sive environments
The handset fulfils the requirements of the ATEX
directive and meets the required EN and IEC stan-
dards (see page 28). See also the notes in the
declaration of conformity in the operating manual.
The OpenStage M3 Ex / OpenStage M3 Ex Plus is
designed for use in potentially explosive working
environments (Ex zones) and complies with fire
prevention regulations. Local and operational fac-
tors may lead to an explosive atmosphere in an Ex
zone. Therefore, please observe the following Ex
safety notes:
Handset:
The handset may only be operated in Ex zones
where it is certified.
Users must check the handset for damage and
verify that it is operating correctly before using it
in the Ex zone. A damaged handset or a handset
that is not fully functional may not be brought
into or used in the Ex zone.
The cover of the battery compartment must be
tightly screwed on to satisfy the Ex protection
and IP rating IP65 (casing protection) require-
ments in an Ex zone.
Deactivate the handset immediately and remove
it from the Ex zone if the following situations
occur:
– You notice damage to the handset.
– You notice damages to the battery.
– If liquids have seeped into the handset.
Replace a damaged handset immediately.
Only employees of Unify Software and Solutions
Software and Solutions GmbH & Co. KG with Ex
zone training and authorisation should repair and
service the handset.
When replacing a malfunctioning device/battery,
the technician must return the malfunctioning
17