Herunterladen Inhalt Inhalt Diese Seite drucken

Operation Mode And Temperature Setpoint; To Start/Stop Operation Mode And To Set The Temperature; Airflow Rate - Daikin ATXF25A5V1BB Betriebsanleitung

Vorschau ausblenden Andere Handbücher für ATXF25A5V1BB:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 11
Feature
To adjust the amount of air blown into

Airflow rate

the room.
To run more quietly.
Advanced features
To use the system when you are also
Econo
using other power-consuming
appliances.
To save energy.
To provide a comfortable airflow that
Comfort
does NOT come in direct contact with
people.
To cool down or heat up the room
Powerful
quickly.
To automatically turn ON or OFF the
ON timer +
OFF
system.
timer
4.3
Operation mode and temperature
setpoint
When. Adjust the system operation mode and set the temperature
when you want to:
▪ Heat up or cool down a room
▪ Blow air in a room without heating or cooling
▪ Decrease the humidity in a room
What. The system operates differently, depending on the user
selection.
Setting
The system cools down or heats up a
Automatic
room to the temperature setpoint. It
automatically switches between cooling
and heating if necessary.
The system decreases the humidity in a
Drying
room.
The system heats up a room to the
Heating
temperature setpoint.
The system cools down a room to the
Cooling
temperature setpoint.
The system only controls the airflow
Fan
(airflow rate and airflow direction).
The system does NOT control the
temperature.
Additional info:
▪ Outside temperature. The system's cooling or heating effect
decreases when the outside temperature is too high or too low.
▪ Defrost operation. During heating operation, frost might occur on
the outdoor unit and decrease the heating capacity. In that case,
the system automatically switches to defrosting operation to
remove the frost. During defrosting operation, hot air is NOT
blown from the indoor unit.
ATXF25~35A5V1B
Daikin room air conditioner
3P520336-8D – 2019.02
Tasks
Description
4.3.1
To start/stop operation mode and to set
the temperature
: Unit is operating.
: Operation mode = Automatic
: Operation mode = Drying
: Operation mode = Heating
: Operation mode = Cooling
: Operation mode = Fan only
: Shows the set temperature.
1 Press
one or more times to select the operation mode.
Result: The mode will be set in the following sequence:
2 Press
to start operation.
Result:
is displayed on the LCD.
Result: The operation lamp lights up.
3 Press
or
on the
raise the temperature.
Note: When using drying or fan only mode, you cannot adjust the
temperature.
4 Press
to stop operation.
Result:
disappears from the LCD.
Result: The operation lamp goes off.
4.3.2
Airflow rate
1 Press
to choose:
5 airflow rate levels, from "
Automatic airflow rate operation
Indoor unit quiet operation. When the airflow rate is
set to "
", the noise from the unit will be reduced.
INFORMATION
▪ If the unit reaches the temperature setpoint in cooling
or heating mode, the fan will stop operating.
▪ When using drying operation mode, you CANNOT
adjust the airflow rate setting.
To adjust the airflow rate
1 Press
to change the airflow setting as follows:
4 Operation
button one or more times to lower or
" to "
"
Operation manual
5

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Atxf35a5v1bb

Inhaltsverzeichnis