Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
Children as well as adults with physical, mental and/
or sensoric impairments must not use this product
without proper supervision. Persons under the influ-
ence of alcohol or drugs are prohibited from using
this product.
The shower system may only be used for bathing,
hygienic and body cleaning purposes.
The hot and cold supplies must be of equal pres-
sures.

Installation Instructions

• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be oberserved.
• The product is not designed to be used with steam
baths!
Thermostatic mixer in conjunction with
combination boilers
• If fitting a hand shower remove the water limiter from
the shower.
• If the continuous water heater causes any problems,
or you have different water pressures you must
install a water limiter to the cold supply, (ordered
separately,article number 97510000).
• Thermostatic mixer Shower: When mounting the
ECOSTOP limit stop washer (Art. No. 98916000) in
connection with flow heaters, turn it axially through
180° before attaching it.
6
English
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
Connections G 1/2:
Centre distance:
• Safety against backflow
• The product is exclusively designed for drinking water!
Symbol description
Do not use silicone containing acetic acid!
Safety Function (see page 25)
The desired maximum temperature for exam-
ple max. 42º C can be pre-set thanks to the
safety function.
Adjustment (see page 24)
After the installation, the output tempera-
ture of the thermostat must be checked. A
correction is necessary if the temperature
measured at the output differs from the
temperature set on the thermostat.
ECOSTOP (see page 26)
Dimensions (see page 30)

Flow diagram

(see page 30)
max. 1 MPa
0,1 - 0,5 MPa
max. 1,6 MPa
max. 80°C
65°C
max. 70°C / 4 min
cold right - hot left
150 ±12 mm

Werbung