Herunterladen Inhalt Inhalt Diese Seite drucken

fluidra Aquasphere 74148 Bedienungsanleitung Seite 25

Für aufstell-und einbaubecken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 94
6.2.5 System reset function
Press
and
6.2.6
Symbol of heating, the light will be on when it is in operation.
When defrosting, the light will flash.
6.2.7
Symbol of automatic stop, the light will be on when it is in operation.
Note: When parameter P6 is on checking/adjusting, Symbol of automatic stop light
6.2.8
Symbol of automatic start, the light will be on when it is in operation.
Note: When parameter P5 is on checking/adjusting, Symbol of automatic start light
6.2.9
Press this button, the light will be flash,
6.2.10
While you choose the Smart, the heat pump will just operate in 'Small output' , 'Medium output' and 'Full output'
When in 'Small output', the lamp of Smart is lighting, the light of Silent will be flash.
When in 'Medium output', the light of Smart will flash.
When in 'Full output', the lamp of Smart is lighting, the lamp of Powerful will be flash.
6.2.11
While you choose the Silent , the heat pump will just operate in 'Medium output' and 'Small output'
When in 'Small output', the light of Silent will flash.
When in 'Medium output', the lamp of Silent is lighting, the lamp of Smart will be flash
7. Troubleshooting
7.1 Error code display on LED wire controller
Malfunction
Inlet water temperature
sensor failure d1-TH6
Outlet water temperature
sensor failure d2-TH5
Heating piping sensor failure
d5-TH2
Ambient temperature sensor
failure d3-TH1
Exhaust piping sensor failure
d6-TH3
in 10s, the system will reset and display "0000" on the controller.
the heat pump will operate in 'Full output' only.
Error
code
1. The sensor in open or short circuit
PP01
2. The wiring of sensor is loose
1. The sensor in open or short circuit
PP02
2. The wiring of sensor is loose
1. The sensor in open or short circuit
PP03
2. The wiring of sensor is loose
1. The sensor in open or short circuit
PP05
2. The wiring of sensor is loose
1. The sensor in open or short circuit
PP06
2. The wiring of sensor is loose
Reason
21
will be flash.
will be flash.
Solution
1. Check or change the sensor
2.Re-fix the wiring of the sensors
1. Check or change the sensor
2.Re-fix the wiring of the sensors
1. Check or change the sensor
2.Re-fix the wiring of the sensors
1. Check or change the sensor
2.Re-fix the wiring of the sensors
1. Check or change the sensor
2.Re-fix the wiring of the sensors

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis