PROTECTIVE FUNCTIONS

FROST PROTECTION FUNCTION
If the exhaust hose temperature is too low in cooling, dehumidification or energy saving mode, the appliance automatically
switches to the protection state. If the exhaust hose temperature rises to a certain temperature, the appliance automatically
returns to normal operation.
OVERFLOW PROTECTION FUNCTION
When the water level in the inner water tank exceeds the warning level, the appliance will automatically emit a warning
signal and "FL" will appear in the LCD temperature display area. In this case, the inner water tank needs to be emptied.
After emptying the tank, the appliance automatically returns to its original state.
AUTOMATIC DEFROST (ONLY MODELS EQUIPPED WITH COOLING HAVE THIS FUNCTION)
The appliance has an automatic defrost function: during defrosting, the heating symbol will flash on the display.
AUTOMATIC THERMAL PROTECTION
To prolong its service life, the appliance is equipped with an automatic thermal protection function. As soon as the
protection is activated, the compressor and the motor stop and after cooling the appliance automatically returns to the
normal heating state.
COMPRESSOR PROTECTION FUNCTION
To prolong its service life, the compressor is equipped with a protection function of a three-minute start delay.

EMPTYING THE INNER WATER TANK

MANUAL DRAIN
When the inner water tank is full, the appliance stops working.
Switch off the appliance and unplug it. Avoid moving the appliance sharply, as this could cause water to spill out of the
inner tank.
Place a suitable container under the water drain plug or move the appliance to a place where the water can be drained.
Unscrew the drain plug cap and remove the rubber plug (1) - water flows out of the inner tank (2).
After draining, replace the rubber plug and screw the drain plug cap back in place.
PERMANENT DRAIN
Unscrew the drain plug cap and remove the rubber plug. Connect the water drain pipe to the drain.
You can connect this pipe to an existing waste system, direct it out and use a gravity gradient or use a water pump.
Note: This model is equipped with a self-evaporating function that reduces the frequency of the required emptying of
the water tank. If the unit is properly ventilated, most of the water is used to cool the condenser coil and the excess is
evaporated. Do not use the permanent drain if you want to use the self-evaporating function.
1
70

CLEANING AND MAINTENANCE

SWITCH OFF AND DISCONNECT THE APPLIANCE BEFORE CLEANING OR PERFORMING ANY MAINTENANCE
SURFACE CLEANING
Wipe the surface of the appliance with a damp soft cloth. Do not use chemicals such as organic solvents, alcohol, benzine,
etc., otherwise the surface or internal functions of the appliance may be damaged.
AIR FILTER CLEANING
If the filter insert is clogged with dust, the efficiency of the air conditioning unit will be reduced. The filter insert should
be cleaned every two weeks or as often as needed in your environment.
CLEANING THE TOP FILTER INSERT FRAME
With both hands, grasp the edge of the evaporator filter insert frame. Pull it out and remove the filter insert from the
frame. If used, unscrew the screws holding the filter before removing (as shown in the figure above).
Place the evaporator filter insert in warm water with a neutral detergent (approx. 40 °C / 104 °F) and dry in a shady place
after cleaning and rinsing.
CLEANING THE LOWER FILTER INSERT FRAME
Grasp the handle of the insert frame of the air intake filter and gently pull it out to remove it. Place the filter insert in warm
water with a neutral detergent (approx. 40 °C / 104 °F) and dry in a shady place after cleaning and rinsing.
MAINTENANCE AT THE END OF THE SEASON
1. Remove the rubber plug and drain plug cap from the drain opening and empty the inner tank. You can also drain
the water by tilting the unit.
2. Then switch the unit to low fan speed mode.
3. Leave the unit in this mode for half a day - until the hose is dry. This helps keep the inside of the appliance dry and
prevents the formation of mould.
4. Switch off the unit and pull the plug out of the socket.
5. Replace the rubber plug and the drain plug cap.
6. Roll up the cable and tie it, then insert it into the accessory compartment.
7. Disconnect the air exhaust hose and store it securely.
8. Cover the appliance and store it in a dry place.
9. Remove the batteries from the remote control and store or dispose of them safely. Keep all accessories for this