AXIS A1601 Network Door Controller
-
This product is not intended for outside wiring as covered by Article 800 in the
National Electrical Code, NFPA 70.
Connectors
-
Power Connector – For UL security applications, the product shall be powered
by a UL 294 listed, UL 293 listed, or UL 603 listed, depending on application,
Class 2 low-voltage power SELV and limited power supply with appropriate
ratings.
-
External power to relays - If the relays are connected to an external power
source this must be UL 294 listed, UL 293 listed, or UL 603 listed, depending
on application,Class 2 low-voltage power SELV and limited power supply.
-
Network Connector – Standard Ethernet wiring. Evaluated by UL when
powered from AXIS T8133 Midspan 30 W 1-port in PoE Mode B. Do not use for
UL 293 installations.
-
Battery input is for connection to a listed UPS and has not been evaluated
by UL to UL 294 or UL 293.
-
Supervised inputs were not evaluated by UL for burglar use.
System considerations
-
Monitoring software was not evaluated by UL, and is for supplemental use.
Maintenance instructions
-
For maintenance instructions and for information about how to configure the
Axis product, see the User Manual.
Further information
-
Card formats verified by UL: ISO Cards Mifare 1K, 32 bits.