AXIS A1601 Network Door Controller
Buttons

Control button

The control button is used for resetting the product to factory default settings. For more
information, see the User Manual.
Connectors

Network connector

RJ45 Ethernet connector with Power over Ethernet Plus (PoE+).
UL: Power over Ethernet (PoE) shall be supplied by a UL 294 listed Power over Ethernet IEEE
802.3af/802.3at Type 1 Class 3 or Power over Ethernet Plus (PoE+) IEEE 802.3at Type 2 Class 4
power limited injector that provides 44–57 V DC, 15.4 W / 30 W. Power over Ethernet (PoE) has
been evaluated by UL with AXIS T8133 Midspan 30 W 1-port.
Reader connector
Two 8–pin terminal blocks supporting both RS485 and Wiegand protocols for communication
with the reader.
The specified power output values are shared between the two reader ports. It means that 486 mA
at 12 V DC is reserved for all readers connected to the door controller.
Select which protocol to use in the product's web page.
Configured for RS485
Function
DC ground (GND)
DC output (+12 V)
RX/TX
Pin
1
2
3–4
Note
Supplies power to
reader.
Full duplex: RX. Half
duplex: RX/TX.
20
Specifications
0 V DC
12 V DC, max
486 mA combined
for both readers