Note
It is recommended to use twisted and shielded cables. Connect shielding to 0 V DC.
Door connector
Two 4-pin terminal blocks for door monitoring devices (digital input).
Only door monitor supports supervision with end of line resistors. If the connection is
interrupted, an alarm is triggered. To use supervised inputs, install end of line resistors. Use the
connection diagram for supervised inputs. See page 22.
Function
Pin
1, 3
DC ground
Input
2, 4
Important
The qualified cable length is up to 30 m (98.4 ft) if the following cable requirement is
met: AWG 24.
Relay connector
Two 4-pin terminal blocks for form C relays that can be used, for example, to control a lock or
an interface to a gate.
Function
Pin
1
DC ground
(GND)
AXIS A1601 Network Door Controller
Notes
For communicating with door monitor.
Digital input or Supervised input —
Connect to pin 1 or 3 respectively to
activate, or leave floating (unconnected)
to deactivate.
Notes
23
Specifications
0 V DC
0 to max 30 V DC
Specifications
0 V DC