Installation
Fig. 84 Laser module with hoses

Hose connections

Note: Trim down the hose end straight if a used hose shows collet traces.
Fig. 85 Hose connection
Fig. 86 Laser module hose connection
86
Connect the hoses (Fig. 84/1).
Push hose (Fig. 85/5) into the hose connector (Fig.
85/1) until the resistance of the collet (Fig. 85/3)
can be felt.
Exert strong pressure to slide the hose approx. 2-3
mm through the O-ring (Fig. 85/2) (second resis-
tance).
Slightly pull back the hose so the collect grips the
hose. The distance between the cap (Fig. 85/4)
and the connector is then approx. 1 mm.
Please note that just like with the compressed air
connection you must overcome a resistance twice
with the connections on the laser module: the first
with the collet, the second with the O-ring.
You can tell that a hose was pushed into the con-
nector far enough if the visible part of the metallic
sleeve is smaller than 5 mm (Fig. 86).
Again, you must pull back the hose somewhat so
the collet grips the hose.
Align the hoses as shown in Fig. 84/1.