Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 10
GB

6 - MAINTENANCE AND STORAGE

Keep the system in a place that does not freeze.
Incidents
The red indicator
(3) lights up.
The pump starts
and stops all the
time.
The pump does
not work.
For any other anomaly, contact our after-sales service. For safety reasons, only the Hozelock-Exel after-sales
service is entitled to disassemble the pump.
7 - OPERATING ANOMALIES / SOLUTIONS
Causes
No water.
1- The circuit is not sealed.
2- Probable presence of foreign
bodies inside the Tecnotronic.
1- The pump has broken down.
2- The Tecnotronic is maybe
blocked with limescale.
3- The pump is not primed.
Restore the water supply.
1-Check the circuit and the different con-
nections to the pump.
2- Disconnect the power supply, remove the
Tecnotronic from the pump and rinse it
completely with a water jet through the entry
side (8), with a garden hose for example.
1- After disconnecting the Tecnotronic from
the pump electrically and hydraulically, try to
make the pump work alone by connecting it
to the power supply.
2- If, through the exit hole (5), you see that
the check valve is jammed,wash it by filling
the Tecnotronic with vinegar or another anti-
limescale product throughthe exit hole. If the
check valve is operating correctly, contact
the after-sales department.
3- Prime the pump (see the pump instruc-
tions)
- see chapter 5 of these instructions
8
Solution

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

7616

Inhaltsverzeichnis