Industrieprotokolle
16.3 EtherNet/IP
Tab. 56:
Id
Attribute
0x1 Status
0x2 Interface Capability
flags
0x3 Config Control
0x4 Physical Link Object Get
0x5 Interface
Configuration
0x6 Host Name
0x7 Safety Network
Number
0x8 TTL Value
374
Attribute der Instanz 1
Access
Rule
Get
Get
Set/Get DWORD
Set/Get STRUCT of:
Set/Get STRING
Get/Set USINT
Data type
DWORD
DWORD
STRUCT of:
UINT PathSize
EPATH Path
UDINT IpAddress
UDINT Netmask
UDINT
GatewayAddress
UDINT NameServer1
UDINT NameServer2
STRING DomainName
Description
0: Interface Status
(0=Interface not configured,
1=Interface contains valid
config)
6: ACD status (default 0)
7: ACD fault (default 0)
0: BOOTP Client
1: DNS Client
2: DHCP Client
3: DHCP-DNS Update
4: Configuration setable (within
CIP)
Other bits reserved (0)
7: ACD capable (0=not capable,
1=capable)
0: 0x0=using stored config
0x1=using BOOTP
1:
0x2=using DHCP
2:
3:
4: One device uses DNS for
name lookup (always 0
because it is not supported)
Other bits reserved (0)
Path to the Physical Link Object,
always {0x20, 0xF6, 0x24, 0x01}
describing instance 1 of the
Ethernet Link Object.
IP Stack Configuration (IP-
Address, Netmask, Gateway, 2
Name servers (DNS, if supported)
and the domain name).
Host Name (for DHCP DNS
Update)
Not supported
Time to live value for IP multicast
packets Range 1..255 (default =
1)
UM Config RSPE
Release 8.6 12/2020