Herunterladen Inhalt Inhalt Diese Seite drucken

Cable Layout; Maintenance; Electrical Connection - belfox Jupiter 250 Montageanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

19. Cable layout

The operator is already equipped with a supply cable (12 V) measuring 100
cm. The connections of the end switches are wired in the crankcase and
don't have to be installed outsides.
By a length of 4 meters, the diameter of the wire connecting the motor and
2
the control board must be equal to 2x1,5 mm
.By a length exceeding 4 me-
2
ters, the diameter of the connecting wire must be equal to 2x2,5mm
.

20. Maintenance

Before being commissioned for the first time power-operated gate installa-
tions must undergo a professional security maintenance conducted by an
expert. This maintenance must be repeated at least once a year. The test
book included in the delivery must document the accomplishment as well as
the results of the maintenance.
Regardless of the security maintenance the drive shaft should be cleaned
using a cloth once a year. Moreover it should be treated with a little silicone
aerosol.

21. Electrical connection

Obtain the relevant information using the mounting instructions "motor con-
trol 47-31-250".
22

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis